2014年1月7日星期二

mine blower FD series mine rotating axial blower

Introduction
FD series mine rotating axial blower is mainly used in non-coal mine, for mine mining face of the long-distance ventilation. A new generation of versatile new energy-saving blower,
Advantages
With a reasonable structure, complete specifications, high efficiency, energy-saving effect, low noise, air distance and other characteristics. Roadway length 2000m or less time to move the fan normal air supply, reducing the labor intensity, saving ventilation time, non-coal mine local ventilation is the ideal equipment.
FD series mine rotating axial blower is composed by two working hosts, two opposite directions by rotation of the impeller. Ie, a clockwise rotation of the impeller, the impeller rotates counterclockwise two, two leaf number relatively prime. An impeller to gain energy from the air by two impellers pressurized sent. Two impellers in addition to increasing energy flow, but also both the static ordinary axial fan vanes function to get oriented in the circumferential direction of the velocity components straightening at the same time, streamline the flow impact, increasing the flow of energy, reducing the wake vortex , reducing the noise.
FD series mine rotating axial blower using outsourcing double silencer, with low noise characteristics, constraints underground space for changing noise environment effect is remarkable.
FD series mine rotating axial blower body with steel plate welding structure, blade and chassis internal use corrosion proof treatment, so that the fan can run for long hours in a wet environment, effectively solve the other conditions caused by corrosion of the fan problem.
FD series of mine rotating axial supporting local fan motor is Y series three-phase asynchronous motor, the voltage rating of 380V. Fans can be set without stopping the machine plus drain devices to ensure the fan in operation for injection drain to ensure the long-term electrical reliability in harsh environments safe operation.
FD series mine rotating axial blower gas ambient temperature -20 ~ +40 , relative humidity less than 95% (25 when), should not exceed 1000m altitude environment. Fan transmission medium dust content shall not exceed 200mg/m3. Fan main conveying air and non-corrosive not spontaneous, non-sticky material medium, dust content shall not exceed 200mg/m3.
Technolgy parameter
model
Rotary speedr/min
Air volumem3/min
Full pressurePa
Model type
matched powerkW
№4.0
2900
136~89
256~2050
Y90L-2
2×2.2
150~100
325~2500
Y100L-2
2×3
165~109
375~3040
Y112M-2
2×4
№5.0
2900
217~145
275~2060
Y112M-2
2×4
240~161
325~2540
Y132S1-2
2×5.5
266~178
400~3155
Y132S2-2
2×7.5
№5.6
2900
286~188
275~2850
Y132S2-2
2×7.5
324~215
375~3690
Y160M1-2
2×11
358~238
440~4560
Y160M2-2
2×15
№6.3
2900
410~237
400~4775
Y160M2-2
2×15
442~256
460~5475
Y160L-2
2×18.5
468~274
525~6125
Y180M-2
2×22
518~318
640~7310
Y200L1-2
2×30
№7.1
2900
608~352
523~6228
Y200L1-2
2×30
652~377
602~7163
Y200L2-2
2×37
696~402
686~8161
Y225M-2
2×45
№8.0
2900
817~473
605~7200
Y225M-2
2×45
874~506
692~8230
Y250M-2
2×55
970~560
850~9950
Y280S-2
2×75
№9.0
1450
831~480
394~4710
Y200-4
2×30
890~520
450~5120
Y225S-4
2×37
950~550
520~6170
Y225M-4
2×45
№10.0
1450
1171~677
514~6131
Y250M-4
2×55
1300~750
630~7540
Y280S-4
2×75
1380~800
710~8520
Y280M-4
2×90
№11.2
1450
1650~950
650~7690
Y280M-4
2×90
1770~1020
750~8790
Y315S-4
2×110
1880~1090
850~9930
Y315M-4
2×132