Liquid control valve specific
classification
Hydraulic control
valve is a valve in the direction control. According
to the direction control valve in hydraulic system function
is divided intoone-way valve and valve two categories. A one-way valve withordinary
one-way valve and check valve in the hydraulic transmission.
Liquid control valve application
(1)To keep the pressure on, slide
valve has a valve leakagephenomenon, only a short time
packing. When packing requirements,can be added
to a liquid control one-way valve in the oil, the
cone valve closed tight, make oil long time pressure.
(2)Supporting hydraulic
cylinder "". In the vertical cylinder, since the slide
valve and pipe leaks, the piston and piston rod of gravity, may
causethe piston and piston rod down. The hydraulic
control one-way valve is connected to the
oil hydraulic cylinder, can prevent the hydraulic cylinder
piston and slide activities such as part of the decline.
(3)Hydraulic
cylinder locking. When the valve is in place, the
two liquid control one-way valve is closed, can be tightly
closed hydrauliccylinder two chamber oil, when the piston
can not move because of external force generated.
(4)Large flow discharge of
oil. Effective working area of hydraulic cylinder two
chamber is great. When the piston back, the right cylinder
chamber row oil suddenly increased, if the small flow of
slide valve,throttling effect will have, restrict the speed of the piston
back; if an additional liquid control one-way valve, the hydraulic cylinder
piston back, the control pressure oil liquid control
one-way valve is opened, it can be smoothly the
right cavity fluid discharge.
(5)For oil filled valve. Vertical
hydraulic cylinder piston at high speed down the
process, because the role of high-pressure oil and weight,resulting in
decreased rapidly, resulting in air and vacuum suction,must add up
oil installations. Fluid control valve used as filling oil
valve, oil supplement to complete.
(6) Combined valve.
In the design of hydraulic
circuit, sometimes can be a liquid control one-way
valve combination valve to use. For example: with two
liquidcontrol one-way valve and a check valve in parallel (one-way Fa
Juzhong), equivalent to a three position three way
reversing valvereversing loop. Needs to point out, the control
pressure oil port does not work, should it pass back to the
tank, otherwise the control pistonis difficult to reset, the
one-way valve can not close the reverse flow.
Liquid control valve note
In practice, a hydraulic control
one-way valve in the use of prone
torepair process, the matters needing attention.
(1)Must ensure that the hydraulic
control one-way valve controls the pressure enough, absolutely not
allowed to control the pressure loss of pressure. Should pay
attention to whether the control pressure to meet the requirements of
the reverse turn. If the check valve controllead independent
system, will have to analyze the change of the main system
pressure control circuit pressure, so as to avoid
themalfunction of hydraulic control valve.
(2)According to the check valve in the
hydraulic system of the position or
reverse oil cavity fluid flow
resistance (pressure) size, structurereasonable selection
of hydraulic control one-way valve (simple or
compound) and drain means (within the vent or leak). For the
drain type check valve, when the reverse oil outlet pressure
exceeds a certain value, the hydraulic control section will
lose control, so the vent type liquid control one-way
valve is generally used to reverse the oil chamber without low
pressure or back pressure of the occasion;the leakage type check valve can
be used to reverse the oil cavitypressure the
high places, to reduce the minimum control pressure, the power
saving control. The system if
the unloading type, piston cylinder will be sent down
intermittent vibration and noise.