Anti-shock wave
door mainly used for mining Inclined wellhead. When the mine danger, the shock
wave washed out the blast doors open, release and played the role of shock
mitigation Inclined Wells.
Anti-shock Wave Door Instructions
1.This
design is suitable for ventilation and maximum negative pressure for 350 mm water column fan for draw out
type;
2.Package
number 7 application in welded steel pipe in the wind, don't use shall be
properly kept in normal working conditions;
3.Explosion
door transportation should take necessary measures to prevent the deformation;
4.Explosion
door frame installation should cooperate closely with mining professional,
beware of deformation;
5.With the door
frame and door leaf, and strive to close the door frame column in the back with
rubber to prevent air leakage;
6.Package
number 3 hinges lubrication when installation to ensure that the flexible;
7.Explosion
door all ZhangDan should wear red, with black paint.
Anti-shock Wave Door Requirements and Methods
1.Installation
requirements
When installation, in accordance with the installation method, should be
straight flat after installation, open and flexible. Then explosion door
closed, place the stop lever in the frame on both sides of the fixed frame, and
the outer side of the door with sand or soil buried below 10 centimeters.
2.Installation
method
(1)
first of all to sort out and measurement of roadway width and height of the
mouth, guarantee the explosion door up with (including) into a whole.
(2)
please send two doors flat on the ground, tidy up the middle of the two sealing
rubber, use bolt to fix two good, that is to be installed.
(3) the
direction of adjustment to ensure that the explosion door open outward, only
then two doors and stand on the wellhead.
(4)
After adjustment, the whole door with a wooden pole fixed.
(5)Press
Start drywall fixed wellhead design.
(6) wall
solidified, the blast doors closed, the lever placed on the door frame on both
sides of the bracket and the bottom of the outer door to door with gravel or
soil buried 10 cm ,
can be used normally.
Anti-shock Wave Door Maintenance
(1)
Where there is rust knocked off or material at any time shall be painted up.
(2) rubber seal
if damaged or unglued should be replaced or bonding, sealing strip replacement
period is 2 years.
(3) Door hinge
rotating part if rust should be cleaned and should be re-oiled.
To choose the
right product, Shandong Coal preferential prices, good service and the best
quality, to ensure your satisfaction!