2013年12月26日星期四

MFHSL Series Fire Gate

MFHSL Series Fire Gate Product Introduction
MFHSL Series Fire Gate used in between the main drainage pump and main substation underground cavern; Mining area substation channel; Belt conveyor, winch power distribution channels such as electrical equipment and substation cavern, such as underground fires, the burning non-proliferation, ensure the safety of mine.
Mainly acts as quarantine personnel, the purpose is to prevent the non-professional personnel into important places; Fire protection fence and gate in the dangerous environment can have the effect of isolation of fire, to prevent the fire from spreading.
MFHSL Series Fire Gate Model and Specification
 Model and Specification
 Drawing No.
 MFHSL1.4*1.8
B85-373.29
MFHSL1.6*1.8
B85-373.30
MFHSL1.8*2.0
B85-373.31
 MFHSL2.1*2.0
B85-373.32
MFHSL 1.4*1.8 MFHSL(Fire gate) 1.4(through the cave mouth net width1400mm) 1.8(through the cave mouth net height 1800mm)
MFHSL Series Fire Gate Conditions of Use
1Work environment :-3040 Wind pressure:03800Pa
2Fire protection fence and gate used in the coal mine coal and methane explosive gases in dangerous places.

3Fire protection fence and gate installation location roadway stability, roadway deformation is small, and no serious watering.

没有评论: